lambda

Staff Electrical Engineer - Low Voltage

Listed by employer · Checked

Posted within 60 days ·

  • hybrid
  • FullTime
  • Data Center Business
  • San Francisco Office (Fremont St)
  • San Jose Office (First St)
Work arrangement
hybrid
Employment
FullTime
Stated compensation
USD 349,000–465,000 1 YEAR
Apply on company website ↗
01 / A QUICK CHECK BEFORE YOU APPLY

Does the location policy fit?

Choose where you would work from. We’ll compare it with the posting’s stated requirements.

Choose the country you will work from. You can change this anytime.

Country and sponsorship changes take effect when you click Check eligibility.

Choose a country to check geographic compatibility. The source requirements are available below.

Source: ashbyChecked Original posting ↗

Requirements

1 with evidence8 unclear or unstated
Remote policy
hybrid
“Provider workplace type: hybrid”
From employer posting metadata
Employment type
FullTime
Compensation
USD 349,000–465,000 1 YEAR
8 fields not stated in this posting
Employer sponsorship
Not specified
Geographic scope
Not specified
Degree requirement
Not specified
Security clearance
Not mentioned
Timezone / hours
Not specified
Citizenship requirement
Not mentioned
Minimum experience (years)
Not specified
Work authorization
Not specified

These details were not stated in the tracked posting. Confirm with the employer.

READ IT IN THE EMPLOYER’S OWN WORDS

Original job description

Reading view uses normalized posting text so exact evidence excerpts can be highlighted.

Lambda, The Superintelligence Cloud, is a leader in AI cloud infrastructure serving tens of thousands of customers. Our customers range from AI researchers to enterprises and hyperscalers. Lambda's mission is to make compute as ubiquitous as electricity and give everyone the power of superintelligence. One person, one GPU. If you'd like to build the world's best AI cloud, join us. *Note: This position requires presence in our San Francisco or San Jose office location 4 days per week; Lambda’s designated work from home day is currently Tuesday.
Read full descriptionShow less description
What You’ll Do Own electrical design standards and reference architectures for low-voltage systems supporting high-density AI infrastructure. Lead design from transformer secondary through switchgear, UPS systems, distribution equipment, busway, and rack-level power delivery. Develop architectures for 480V and 415V, AC systems serving GPU clusters and supporting infrastructure. Define requirements for low-voltage switchgear, switchboards, UPS systems, static transfer switches, PDUs, RPPs, busway, rack PDUs, grounding, metering, and monitoring. Model equipment loads, GPU power behavior, transient demand, harmonics, redundancy, capacity, and electrical failure domains. Develop and review single-line diagrams, panel schedules, equipment specifications, sequences of operation, and basis-of-design documents. Evaluate greenfield, retrofit, and partner-provided designs for reliability, efficiency, maintainability, constructability, cost, and schedule. Perform or oversee load-flow, short-circuit, selective-coordination, arc-flash, voltage-drop, and power-quality studies. Coordinate electrical requirements across data center facilities, mechanical systems, HPC architecture, hardware engineering, construction, and operations. Support equipment selection, factory testing, construction sequencing, commissioning, integrated systems testing, and root-cause investigations. Travel to project sites, manufacturers, and partner facilities as needed. You Have experience designing low-voltage electrical systems for data centers, mission-critical facilities, or large industrial environments. Understand low-voltage distribution, UPS topologies, switchgear, busway, grounding, rack-level distribution, and electrical monitoring. Understand redundancy models such as N, N+1, 2N, distributed redundant, and catcher architectures. Can develop and review single-line diagrams, equipment specifications, coordination studies, and commissioning documentation. Have experience with ETAP, SKM, EasyPower, or comparable electrical analysis software. Understand applicable electrical and safety requirements, including NEC, NFPA 70E, IEEE, and NETA standards. Can translate IT equipment requirements into safe, scalable, and maintainable facility designs. Communicate clearly across engineering, construction, operations, vendors, and executive stakeholders. Hold a bachelor’s degree in electrical engineering or equivalent practical experience. Nice to Have Experience with hyperscale, colocation, HPC, or AI data centers. Experience delivering power to high-density GPU racks or liquid-cooled computing infrastructure. Familiarity with dynamic GPU loads, power transients, harmonics, rack-level monitoring, or power-capacity optimization. Experience supporting factory acceptance testing, commissioning, integrated systems testing, or failure investigations. Experience in Low Voltage (400, 800V DC) Converters, distribution and protection devices. Experience with PSCAD, other EMT simulation tools or System Stability Analysis Professional Engineer licensure or progress toward licensure. Salary Range Information The annual salary range for this position has been set based on market data and other factors. However, a salary higher or lower than this range may be appropriate for a candidate whose qualifications differ meaningfully from those listed in the job description. About Lambda Founded in 2012, with 500+ employees, and growing fast Our investors notably include TWG Global, US Innovative Technology Fund (USIT), Andra Capital, SGW, Andrej Karpathy, ARK Invest, Fincadia Advisors, G Squared, In-Q-Tel (IQT), KHK & Partners, NVIDIA, Pegatron, Supermicro, Wistron, Wiwynn, Gradient Ventures, Mercato Partners, SVB, 1517, and Crescent Cove We have research papers accepted at top machine learning and graphics conferences, including NeurIPS, ICCV, SIGGRAPH, and TOG Our values are publicly available: https://lambda.ai/careers We offer generous cash & equity compensation Health, dental, and vision coverage for you and your dependents Wellness and commuter stipends for select roles 401k Plan with 2% company match (USA employees) Flexible paid time off plan that we all actually use Equal Opportunity Employer Lambda is an Equal Opportunity employer. Applicants are considered without regard to race, color, religion, creed, national origin, age, sex, gender, marital status, sexual orientation and identity, genetic information, veteran status, citizenship, or any other factors prohibited by local, state, or federal law.
Original formatting and links

Lambda, The Superintelligence Cloud, is a leader in AI cloud infrastructure serving tens of thousands of customers. Our customers range from AI researchers to enterprises and hyperscalers. Lambda's mission is to make compute as ubiquitous as electricity and give everyone the power of superintelligence. One person, one GPU.

If you'd like to build the world's best AI cloud, join us.

*Note: This position requires presence in our San Francisco or San Jose office location 4 days per week; Lambda’s designated work from home day is currently Tuesday.


What You’ll Do

  • Own electrical design standards and reference architectures for low-voltage systems supporting high-density AI infrastructure.

  • Lead design from transformer secondary through switchgear, UPS systems, distribution equipment, busway, and rack-level power delivery.

  • Develop architectures for 480V and 415V, AC systems serving GPU clusters and supporting infrastructure.

  • Define requirements for low-voltage switchgear, switchboards, UPS systems, static transfer switches, PDUs, RPPs, busway, rack PDUs, grounding, metering, and monitoring.

  • Model equipment loads, GPU power behavior, transient demand, harmonics, redundancy, capacity, and electrical failure domains.

  • Develop and review single-line diagrams, panel schedules, equipment specifications, sequences of operation, and basis-of-design documents.

  • Evaluate greenfield, retrofit, and partner-provided designs for reliability, efficiency, maintainability, constructability, cost, and schedule.

  • Perform or oversee load-flow, short-circuit, selective-coordination, arc-flash, voltage-drop, and power-quality studies.

  • Coordinate electrical requirements across data center facilities, mechanical systems, HPC architecture, hardware engineering, construction, and operations.

  • Support equipment selection, factory testing, construction sequencing, commissioning, integrated systems testing, and root-cause investigations.

  • Travel to project sites, manufacturers, and partner facilities as needed.

You

  • Have experience designing low-voltage electrical systems for data centers, mission-critical facilities, or large industrial environments.

  • Understand low-voltage distribution, UPS topologies, switchgear, busway, grounding, rack-level distribution, and electrical monitoring.

  • Understand redundancy models such as N, N+1, 2N, distributed redundant, and catcher architectures.

  • Can develop and review single-line diagrams, equipment specifications, coordination studies, and commissioning documentation.

  • Have experience with ETAP, SKM, EasyPower, or comparable electrical analysis software.

  • Understand applicable electrical and safety requirements, including NEC, NFPA 70E, IEEE, and NETA standards.

  • Can translate IT equipment requirements into safe, scalable, and maintainable facility designs.

  • Communicate clearly across engineering, construction, operations, vendors, and executive stakeholders.

  • Hold a bachelor’s degree in electrical engineering or equivalent practical experience.

Nice to Have

  • Experience with hyperscale, colocation, HPC, or AI data centers.

  • Experience delivering power to high-density GPU racks or liquid-cooled computing infrastructure.

  • Familiarity with dynamic GPU loads, power transients, harmonics, rack-level monitoring, or power-capacity optimization.

  • Experience supporting factory acceptance testing, commissioning, integrated systems testing, or failure investigations.

  • Experience in Low Voltage (400, 800V DC) Converters, distribution and protection devices.

  • Experience with PSCAD, other EMT simulation tools or System Stability Analysis

  • Professional Engineer licensure or progress toward licensure.

Salary Range Information

The annual salary range for this position has been set based on market data and other factors. However, a salary higher or lower than this range may be appropriate for a candidate whose qualifications differ meaningfully from those listed in the job description.

About Lambda

  • Founded in 2012, with 500+ employees, and growing fast

  • Our investors notably include TWG Global, US Innovative Technology Fund (USIT), Andra Capital, SGW, Andrej Karpathy, ARK Invest, Fincadia Advisors, G Squared, In-Q-Tel (IQT), KHK & Partners, NVIDIA, Pegatron, Supermicro, Wistron, Wiwynn, Gradient Ventures, Mercato Partners, SVB, 1517, and Crescent Cove

  • We have research papers accepted at top machine learning and graphics conferences, including NeurIPS, ICCV, SIGGRAPH, and TOG

  • Our values are publicly available: https://lambda.ai/careers

  • We offer generous cash & equity compensation

  • Health, dental, and vision coverage for you and your dependents

  • Wellness and commuter stipends for select roles

  • 401k Plan with 2% company match (USA employees)

  • Flexible paid time off plan that we all actually use

Equal Opportunity Employer

Lambda is an Equal Opportunity employer. Applicants are considered without regard to race, color, religion, creed, national origin, age, sex, gender, marital status, sexual orientation and identity, genetic information, veteran status, citizenship, or any other factors prohibited by local, state, or federal law.

Similar roles

All lambda jobs →

Matched by role category. Review each posting’s requirements before applying.

THE JOB ELIGIBILITY CHECKER

Check a job